Alterations to the meet the readily achievable requirements of title iii of the americans with disabilities act may be limited the actual work of the project.
Ada restroom stall door requirements. The ada compliant restroom. Slowly opening low powered automatic doors shall comply with ansi a156 19 1984. For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov. They should be usable with one hand without the need to tightly grasp pinch or twist the wrist.
Figure 30 a standard stall. Ada standards for accessible design can be downloaded from www ada. This example shows a door swing located outside fixture clearances obviating the need for wheelchair space beyond the arc of the door swing and turning space free of any overlapping elements left. Toilet rooms can be configured in many different ways but the same requirements apply including those for fixtures doors and turning space.
If an automatic door is used then it shall comply with ansi bhma a156 10 1985. Such doors shall not open to back check faster than 3 seconds and shall require no more than 15 lbf 66 6n to stop door movement. To see all of the ada compliance requirements see the 2010 ada standards for accessible design at www ada gov. These design requirements must be met for most public and commercial bathrooms.
They can also serve as a general guide for safe user friendly accessible design when ada compliance is not required. Examples of ada toilet stalls. 5 common ada restroom compliance mistakes. When ordering ada bathroom toilet stalls please send us your plans so we can quote you.
Or for answers to. A 36 stall door is used most often with a wheel fitting through that opening. Toilet stall doors including door hardware shall comply with 4 13. Alterations to entrances toilet facilities elevators steps handrails to meet the accessibility requirements may be limited to the actual work of the project.
Ada compliant urinals should be stall type or wall hung at a maximum of 17 inches from the floor. The americans with disabilities act ada of 1990 includes specific guidelines for the construction of accessible or ada compliant bathrooms. Need help ordering ada compliant restroom materials. Certain ada compliance issues seem to crop up more frequently than others but it s important to note that the following is not an exhaustive list.
Ada compliance can be overwhelming and we want to help. Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them. Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383. Users shouldn t have to exert more than 5 pounds of force to use the faucet to meet ada requirements.