Ada Toilet Stall Door Swing
The width of the standard stall must be 60in.
Ada toilet stall door swing. Toilet flush levers are also supposed to be installed on the open side of the stall so that the user doesn t have to reach over the toilet meihls adds. Figure 30 a standard stall. The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm. If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
From either side of the stall with a 32in. Toilets must be located within 16 18 inches from the centerline of the wall meihls says. More or less than that makes maneuvering difficult. In addition doors can swing into fixture clearances at single occupant toilet rooms accessed only through a.
Current guidelines for bathrooms published in 2010 allow the bathroom door to swing inward as long as there. Toilet stall doors including door hardware shall comply with 4 13. Doors cannot swing into required clear floor or ground spaces in these specific instances. For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
Multiple toilet stall layouts. The centerline of the water closet is 18 inches 455 mm from the side wall. 603 2 3 exception 2 yes no measurement. An example of a single ada bathroom layout.
The minimum width of the stall is 60 inches 1525 mm. They cannot swing into the clearance required at plumbing fixtures except in single user toilet rooms where clear floor space 30 minimum by 48 minimum is provided in the room beyond the arc of the door swing 603 2 3 ex. Figure 30 a standard stall. Clear floor space at controls for automatic and power assisted doors and gates 404 3 5 fixture clearances in toilet and bathing facilities except those that are single user where wheelchair space beyond the door swing is provided 603 2 3.
In the 2010 standards an exception allows the entry door to swing over the clear floor spaces and clearances required at the fixtures if a clear floor space complying with section 305 3 minimum 30 inches by 48 inches is provided outside the arc of the door swing section 603 3 3 exception 2. Minimum with a floor mounted water closet. In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door. Like any building code ada guidelines are subject to change.
3 18 in a single user toilet room if the door swings in and over a clear floor space at an accessible fixture is there a clear floor space at least 30 x 48 inches beyond the swing of the door. Minimum inside with a wall mounted water closet and 59in. The commode must be centered 18in.